Plastic -insulated Shielded Flame-retardant Control Cable

Availability:
Quantity:
Plastic -insulated Shielded Flame-retardant Control Cable
Plastic -insulated Shielded Flame-retardant Control Cable

PLASTIC -INSULATED SHIELDED FLAME-RETARDANT CONTROL CABLE



STANDARD IMPLEMENTED

GB/T 9330-2020(reference IEC227 withstand voltage)

TEST STANDARD

GB /T2951-1997、GB/T3048-1994、

GB/T18380.3-2001、GB/T1765-1998、

GB/T17650-1998

It applies to the control and protecting lines at a rated voltage U。/U of 450/750V and below.

SERVICE CHARACTERISTICS

Rated voltage Uo/U: 450/750V

Operating Temp: For general type, it should not exceed 70℃; For XLPE type, it should not exceed 90℃. The max. rated temperature of cable conductor is 90℃, and the max. temperature of cable conductor is no more than 250℃ when short circuit less than 5 seconds.

INSTALLATION RECOMMENDATION

1)When cable installation, the ambient temperature should not be lower than 0℃, or, to be preheated.

2)Bending radius: For cables without armor ≥ 6X outer diam. For cables with armor ≥ 12X outer diam.

CONSTRUCTION:

Composition Designation Materials
1.Conductor T Stranded copper conductor
Stranded conductor
2.Insulation layer  YJ Cross-linked polyethylene (XLPE)
3.Filler & tape Non-hygroscopic material
4.Shield P Copper wire
P2 Copper tape
P3 Aluminum-plastic tape
5.Ground wire - Stranded copper wire
6.Wrapping tape Non-hygroscopic material 
7.Inner sheath V Polyvinyl chloride (PVC)
Y Polyethylene(PE), Polyolefin
8.Armor 2 Galvanized steel strip
3 Galvanized fine steel wire
4 Galvanized thick steel wire
6 Non-magnetic strip materials
7 Non-magnetic wire materials
9.Outer sheath 2 Polyvinyl chloride (PVC)
3 Polyethylene(PE), Polyolefin
WDZ Low Smoke & Halogen-free
FSY Rat-proof, ant-proof, water-proof
F Polytetrafluoroethylene
10.Flammability  A Grade A of flame-retardant
B Grade B of flame-retardant
C Grade C of flame-retardant

  

SPECIFICATION DESCRIPTION:

Specification

Description

Application

Cu-core

Al-core

WDZA-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZB-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZC-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZA-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZB-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZC-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZA-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZB-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZC-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZA-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZB-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZC-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

FSY-WDZA-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZB-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZC-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZA-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZA-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZA-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZA-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZB-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZC-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZA-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZB-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZC-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZA-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZB-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZC-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZA-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZB-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZC-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZA-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZB-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZC-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZA-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

FSY-WDZA-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZB-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZC-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZA-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZB-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZC-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZAN-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZBN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZCN-KYJY(R)23

XLPE insulated steel-strip armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZAN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZBN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZCN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZAN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZBN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZCN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

FSY-WDZAN-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZBN-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZCN-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZAN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZBN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZCN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZAN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZBN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZCN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZAN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZBN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZCN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZAN-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored  halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZBN-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored  halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZCN-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZAN-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZBN-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZCN-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZAN-KYJY(R)P(P2)-43


XLPE insulated combined braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZBN-KYJY(R)P(P2)-43


XLPE insulated combined braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZCN-KYJY(R)P(P2)-43


XLPE insulated combined braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZAN-KYJY(R)P(P2)-33


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZBN-KYJY(R)P(P2)-33


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZCN-KYJY(R)P(P2)-33


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZAN-KYJY(R)P(P2)


XLPE insulated combined braiding shielded halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

BP-WDZBN-KYJY(R)P(P2)


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

BP-WDZCN-KYJY(R)P(P2)


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

BP-FSY-WDZAN-KYJY(R)P(P2)-23


XLPE insulated combined braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

BP-FSY-WDZBN-KYJY(R)P(P2)-23


XLPE insulated combined braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

BP-FSY-WDZCN-KYJY(R)P(P2)-23


XLPE insulated combined braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

WDZAN-KYJY(R)P2-23


XLPE insulated copper tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P2-23


XLPE insulated copper tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P2-23


XLPE insulated copper tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P3-23


XLPE insulated aluminium-plastic tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P3-23


XLPE insulated aluminium-plastic tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P3-23


XLPE insulated aluminium-plastic tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P2-33


XLPE insulated copper tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P2-33


XLPE insulated copper tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P2-33


XLPE insulated copper tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P3-33


XLPE insulated aluminium-plastic tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P3-33


XLPE insulated aluminium-plastic tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P3-33


XLPE insulated aluminium-plastic tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

ZAN-KFF(R)P


Polytef insulated copper wire shielded polytef sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZBN-KFF(R)P


Polytef insulated copper wire shielded polytef sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZCN-KFF(R)P



Polytef insulated copper wire shielded polytef sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZAN-KFF(R)P2


Polytef insulated copper tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZBN-KFF(R)P2


Polytef insulated copper tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZCN-KFF(R)P2



Polytef insulated copper tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZAN-KFF(R)P3


Polytef insulated aluminium-plastic tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZBN-KFF(R)P3


Polytef insulated aluminium-plastic tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZCN-KFF(R)P3



Polytef insulated aluminium-plastic tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

Specification

Description

Application

Cu-core

Al-core

WDZA-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZB-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZC-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZA-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZB-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZC-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZA-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZB-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZC-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZA-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZB-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZC-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

FSY-WDZA-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZB-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZC-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZA-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZA-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZA-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZA-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZB-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZC-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZA-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZB-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZC-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZA-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZB-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZC-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZA-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZB-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZC-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZA-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZB-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZC-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZA-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

FSY-WDZB-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

FSY-WDZC-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

FSY-WDZA-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZB-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZC-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZA-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZB-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

FSY-WDZC-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZAN-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)


XLPE insulated halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZBN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZCN-KYJY(R)23

XLPE insulated steel-strip armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZAN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZBN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZCN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZAN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZBN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

WDZCN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force and considerable traction.

FSY-WDZAN-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZBN-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZCN-KYJY(R)


XLPE insulated halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench and pipeline under certain traction. When magnetic pipeline, single-core prohibited.

FSY-WDZAN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZBN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZCN-KYJY(R)23


XLPE insulated steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZAN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZBN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZCN-KYJY(R)33


XLPE insulated fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZAN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZBN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

FSY-WDZCN-KYJY(R)43


XLPE insulated thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline and buried-pipe laying withstanding radial mechanical external force and certain traction.

WDZAN-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P


XLPE insulated braiding shielded halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored  halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P-23


XLPE insulated braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZBN-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored  halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZCN-KYJY(R)P-33


XLPE insulated braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZAN-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZBN-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

WDZCN-KYJY(R)P-43


XLPE insulated braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame-retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZAN-KYJY(R)P(P2)-43


XLPE insulated combined braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZBN-KYJY(R)P(P2)-43


XLPE insulated combined braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZCN-KYJY(R)P(P2)-43


XLPE insulated combined braiding shielded thick steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZAN-KYJY(R)P(P2)-33


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZBN-KYJY(R)P(P2)-33


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZCN-KYJY(R)P(P2)-33


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C

To be laid in water or somewhere with high drop withstanding mechanical external force, considerable traction and interference.

BP-WDZAN-KYJY(R)P(P2)


XLPE insulated combined braiding shielded halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

BP-WDZBN-KYJY(R)P(P2)


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

BP-WDZCN-KYJY(R)P(P2)


XLPE insulated combined braiding shielded fine steel wire armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

BP-FSY-WDZAN-KYJY(R)P(P2)-23


XLPE insulated combined braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade A, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

BP-FSY-WDZBN-KYJY(R)P(P2)-23


XLPE insulated combined braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade B, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

BP-FSY-WDZCN-KYJY(R)P(P2)-23


XLPE insulated combined braiding shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant VFD control cable with flame retardant of Grade C, Rat-proof, ant-proof, and water-proof

To be laid in indoor, cable trench, pipeline, buried-pipe laying and other anti-interference places withstanding radial mechanical external force and certain traction.

WDZAN-KYJY(R)P2-23


XLPE insulated copper tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P2-23


XLPE insulated copper tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P2-23


XLPE insulated copper tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P3-23


XLPE insulated aluminium-plastic tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P3-23


XLPE insulated aluminium-plastic tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P3-23


XLPE insulated aluminium-plastic tape shielded steel-strip armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P2-33


XLPE insulated copper tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P2-33


XLPE insulated copper tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P2-33


XLPE insulated copper tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZAN-KYJY(R)P3-33


XLPE insulated aluminium-plastic tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZBN-KYJY(R)P3-33


XLPE insulated aluminium-plastic tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

WDZCN-KYJY(R)P3-33


XLPE insulated aluminium-plastic tape shielded steel wire armored halogen-free Polyolefin sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference places under certain traction. When magnetic pipeline, single-core prohibited.

ZAN-KFF(R)P


Polytef insulated copper wire shielded polytef sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZBN-KFF(R)P


Polytef insulated copper wire shielded polytef sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZCN-KFF(R)P



Polytef insulated copper wire shielded polytef sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZAN-KFF(R)P2


Polytef insulated copper tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZBN-KFF(R)P2


Polytef insulated copper tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZCN-KFF(R)P2



Polytef insulated copper tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZAN-KFF(R)P3


Polytef insulated aluminium-plastic tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade A

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZBN-KFF(R)P3


Polytef insulated aluminium-plastic tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade B

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.

ZCN-KFF(R)P3



Polytef insulated aluminium-plastic tape shielded polytef sheathed fire-resistant control cable with flame retardant of Grade C

To be laid in indoor, cable trench, pipeline and other anti-interference, high-temperature resistant, and acid and alkali resistant places under certain traction. When magnetic pipeline, single-core prohibited.


Previous: 
Next: 

Our Company

As a professional wire and cable manufacturer founded in 1999, Yangzhou Zhongda Cable Co., Ltd. is located in the northern suburbs of Yangzhou City, which is a famous historical and cultural city with beautiful scenery.

Quick Links

Product Category

Contact Us

We are warm welcome you to join us all the time!
Leave a Message
CONTACT US
Copyright © 2023 Yangzhou Zhongda Cable Co., Ltd. All Rights Reserved. Supported by leadong.com SitemapPrivacy Policy